雅虎香港 搜尋

搜尋結果

  1. The condenser water pump is used to circulate condenser water either in an open or a closed circuit system. The condenser water pump circulates return condenser water from the chiller back to the cooling tower. The cooling tower then cools the condenser water, and the condenser water is supplied back to the chiller.

  2. Subject. Variable Flow Control for Condensing Water Pumps 冷卻水泵: 可變流量控制. Keywords. Variable Flow Control for Condensing Water Pumps冷卻水泵: 可變流量控制. Created Date. 3/10/2010 11:11:57 AM.

    • How Does A Condenser Water System Work?
    • Components of The System
    • Differences Between Chilled Water Systems and Condenser Water Systems
    • Common Pitfalls of The Condenser Water System

    To learn the process in which the system works, first you must understand the refrigeration cycle. The most common method of rejecting heat is through a cooling tower located outside of the building. In these systems, water which is heated by the chiller is pumped to the top of the tower and then descends to the sump basin at the bottom of the towe...

    Cooling towers:Cooling towers reject energy from water-cooled chilled-water systems.
    Condenser water pumps: they supply the required condenser water flow rate and overcome the pressure drop through the chiller’s condenser, the condenser water pipes, elbows and valves, and lift the...
    Chillers: chillers use recirculating condenser water from a cooling tower to condense the refrigerant. They include compressor, condenser, expansion valve, and evaporator.

    Chilled water systems are used to absorb heat energy from within a building or process while condenser water systems are used to remove that heat energy from the building and reject it to the atmosphere.

    Low flow through towers: Every cooling tower has a minimum flow requirement, which is defined by the allowable turndown. Low flow leads to dry air disease and the eventual build-up of mineral depos...

  3. 冷凝器泵是如何工作的? 通过分享. 在大型工业设备中抽水蒸汽时,始终会涉及到一定数量的空气,这些空气要么是夹杂在蒸汽中,要么来自设备泄漏(以下有关空气和水蒸汽的探讨显然一般也适用于水蒸汽以外的其他蒸汽)。 因此,冷凝器必须带 气镇 机械泵作为前级泵(参见图 2.41),而且冷凝器也要像 罗茨泵 一样,始终与前级泵结合使用。 前级泵的作用包括抽除一部分的空气(这部分空气通常在水蒸汽混合物中仅占很小的比例),而不会同时抽取大量的水蒸汽。 因此在静态条件下,如果不进一步考虑,会很难评估冷凝器和前级泵组合在粗真空区域内的流量比。 只是简单地应用连续性方程还不够,因为它不再是一个连续的流量。 这里要特别强调这一点。

  4. Condensate pumps are used in hydronic systems that cannot discharge excess condensate water via a gravity feed. Condensate pumps are usually electrically powered centrifugal pumps. They are used to remove condensate water from HVAC systems that

  5. www.grundfos.com › research-and-insights › condensate-pumpCondensate pump | Grundfos

    A condensate water pump is used to pump condensation water in cooling systems. Condensation must be removed when it forms on cooling surfaces and in cooling systems. The condensate should be collected in a drip tray.

  6. Heat Rejection. Condenser pressure rises with condenser temperature. Compressor work increases as condenser pressure rises. “Heat transfer device, often tower-like, in which atmospheric air cools warm water, generally by direct contact (evaporation).”. cooling tower.