雅虎香港 搜尋

搜尋結果

  1. Flow rate, the quantity of fluid (or volume) that goes through the pump in a specific unit of time. Hydraulic head of a pump, the actual energy that the pump can deliver to the fluid. By examining a generic system like the one shown in the adjacent figure, there are two fundamental measurements: Hg geodetic head.

  2. Imperial Units Zs = suction height from reference, ft //SI Units Zs = suction height from reference, m. Zd. Imperial Units Zd = discharge head from reference, ft //SI Units Zd = Discharge head from reference, m. H = pump head. Imperial Units H = pump head, ft // SI Units H = pump head, m.

  3. 2021年8月21日 · As an engineer, there are times when calculations need to be done quickly, even when all of the desired inputs are not readily available, to determine the best solution. With centrifugal pumps, these calculations typically deal with calculating a pump’s total head

  4. www.pumpfundamentals.com › php_pages › pumpPump head calculator

    Pump head calculator. Flow rate q (gpm): Static head sh (ft) Inside diameter d (in) Pipe or tube length L (ft) Velocity (ft/s) = 5.1. Pipe friction head per 100 ft of pipe (ft/100 ft) = 30.9. Pipe friction head (ft) = 2.5.

  5. calculatorshub.net › measurement-tools › pump-head-calculatorPump Head Calculator Online

    2023年11月29日 · It calculates the pump head (in feet) based on several factors: Hp = (Q * ρ * g * H) / η. Where: Hp is the pump head (in feet). Q is the flow rate (in cubic feet per second or gallons per minute). ρ is the density of the fluid (in pounds per cubic foot or specific gravity).

  6. 2017年9月11日 · To calculate the new pump head pressure from an increase or decrease in pump speed rpm, the following formula and calculation can be used. Calculate head pressure for an increase or decrease in pump speed rpm. To calculate the new pump impeller diameter to suit a change in pump flow rate, the following formula and calculation and be used.

  7. 2019年5月22日 · Pump head: H = Pw / ρgQ = (u2Vt2 – u1Vt1)/g. Given are the following data for a centrifugal water pump: diameters of the impeller at the inlet and outlet. r1 = 10 cm. r2 = 20 cm. Speed = 1500 rpm (revolutions per minute) the blade angle at inlet β1 = 30°. the blade angle at outlet β2 = 20°.

  8. Calculation. How to calculate the pump head ? Equation 1 : Pump Head. With. ps : pressure at suction (bar) pd : pressure at discharge (bar) spgr4t : specific gravity of the liquid processed. us : velocity at suction (m/s) ud : velocity at discharge (m/s) 3. Use of pump head. Pump head is a key piece of information found on pump characteristic.

  9. Calculate the total head and select the pump. Calculate the NPSH available and check with respect to the NPSH required. Calculate the specific speed and predict the pump efficiency. Calculate the suction specific speed and Thoma number and check the prediction of the Thoma number regarding cavitation.

  10. Pump head and flow calculator. Pump/ventilator head vs flow curve calculator. Calculate pump (or ventilator) head and flow for known pipeline size. Description. The calculator allows the analysis of fluid flow through the pipeline for the selected pump size.

  1. 其他人也搜尋了