  1. June 2017. Content - 1. INTRODUCTION. This Code of Practice provides the details of the general principles to be applied to the design of distribution substations, including substations located at ground floor, basement, upper floor level including at high level in high rise building and outdoor areas.

    • 698KB
    • 49
  2. Details. Non-inverter-based RE Systems with generation capacity of up to 200kW. Sets out the general technical requirements for the parallel connection of your RE systems connecting to CLP’s 11 kV or 380V system. Electricity revenue meters. Prepare this document for your online application. Prepare this document for your online application.

  3. Code of Practice No. 101 for Distribution Substation Design Page 17. Version 13.0 June 2014. Drawings No. T-COP-10250-D-E33-0103-16 and T-COP- 10250-D-E33-0103-17 show the details of this type of door. 5.6.1.2 Double leaf door 1500mm wide x 2500mm high shall be provided for 11kV switchgear and personnel access.

  4. You may download our frequently used forms below. If you wish to apply in person, you may visit any of our Customer Service Centres. Apply online Save time and effort ...

  5. cover between the finished floor level and the reinforcement bar of the foundation shall be 80mm. The floor surface shall be flat and within a tolerance of 1mm in 1000mm. 4.5 Earthing Design for Electrical Equipment Earthing design for the electrical equipment

  6. CLP Power Hong Kong Limited is a wholly-owned subsidiary of CLP Holdings Limited. Founded in 1901, we provide electricity to more than 80% of Hong Kong’s population.

  7. 18A 固定電力裝置改裝或增設的規定. 現有的固定電力裝置若要改裝或增設,負責該項工作的註冊電業工程人員應: ( i ) 按照線路規例的規定進行改裝或增設工作; ( ii ) 證實該項改裝或增設工作絕不會有損現有裝置的安全;及 ( iii ) 證實新顏色電線按照附錄18 的要求 ...